how to fix error DHPFKB Rear Pump short circuit ??? check it first !!!
error DHPFKB caused Signal voltage from rear pump pressure sensor increased to 4.5 V or above.
Action of
controller
:
- Fixes travel speed to Lo.
- Continues controls, assuming pressure to be constant {350 kg/cm2}.
- Even if cause of failure disappears, machine does not become normal starting switch is turned to
OFF position.
Problem on
machine
- Rear pump pressure cannot be monitored.
-Travel and work equipment speeds are insufficient.
Related
information
- As T-adapter for pump controller connector is "socket-type box", operating voltage cannot be measured at pump controller connector.
- Input voltage from rear pump pressure sensor can be checked by using monitoring function.
(Code: 01113 Rear pump pressure sensor voltage)
-Method of reproducing failure code: Turn starting switch to ON position or start engine.
-
1:09:13
Man in America
11 hours agoSICK: Xi & Putin Caught Plotting Organ Transplants for “Eternal Life”
86.3K29 -
6:04:35
Drew Hernandez
13 hours agoMASS CONFUSION AROUND CHARLIE'S MURDER
63.8K46 -
1:01:40
HotZone
6 days ago $12.84 earned"Prepare for WAR" - Confronting the URGENT Threat to America
84.9K21 -
20:23
Scammer Payback
14 hours agoTerrifying Scammers with File Deletions
49.7K13 -
16:22
The Gun Collective
10 hours agoWOW! 17 New Guns JUST GOT RELEASED!
65.4K11 -
1:13:57
Glenn Greenwald
11 hours agoYoung Men and Online Radicalization: Dissecting Internet Subcultures with Lee Fang, Katherine Dee, and Evan Barker | SYSTEM UPDATE #516
194K80 -
1:14:57
Sarah Westall
8 hours agoCEO of Crowds on Demand: The Fake World of Social Media, Protests & Movements w/ Adam Swart
75.3K14 -
4:03:25
Geeks + Gamers
11 hours agoTuesday Night's Main Event
85.5K2 -
40:36
RiftTV
10 hours agoHow We Got 400 Leftists FIRED for MOCKING Charlie Kirk | The Rift | Guest: Olivia Krolczyk
83.4K66 -
1:28:58
Badlands Media
1 day agoBadlands Story Hour Ep 134: Godzilla Minus One
51.5K8