11 MORE confusing electrician code terms - UNDERSTANDING THE NEC (PART 2)
Let’s face it…the national electric code book is probably the most difficult construction document to read and understand. It’s written like a court document in legalese, using terms none of us use in the field, for the sake of liability and C.Y.A. These are 11 terms that are used in the NEC that I feel people struggle with understanding when they first buy a code book.
👾🤖PRACTICE EXAMS🤖👾
https://www.electricianu.com/practice-exams
😎👕MERCH👕😎
https://www.electricianu.com/merchandise
📲👥SOCIALS👥📲
Instagram - https://www.instagram.com/electrician_u
Discord - https://discord.gg/7ykYfbh
Facebook Page - https://www.facebook.com/theelectricianu
Facebook Group - https://bit.ly/2tz7eQh
TikTok - https://www.tiktok.com/@electricianu
#1 - BRANCH CIRCUIT
Branch circuits are the most common circuits that we deal with on a daily basis. Branch circuits are the conductors that begin at the last breaker (over-current device) and end at an outlet. Remember from PART 1 of this series that an outlet is not a receptacle, it is a place where power is “taken” from for equipment. You may have multiple electrical panel-boards that have multiple branch circuits coming out of them. Branch circuits come from breakers, but do not feed other breakers. They only feed outlets.
#2 - MULTI-WIRE BRANCH CIRCUIT
Multi-wire branch circuits are similar to standard branch-circuits in that they originate at a breaker and feed outlets. However they differ becuse they have 2 or more circuits in the same cable assembly/conduit. An example of this is 12/3 MC cable. 12/3 has 2 hot (ungrounded) conductors feeding from 2 breakers on different phases, both independent circuits, and a neutral (grounded) conductor all in the same run. Both hots share one neutral. Another example is 12/4 NM (Romex) cable. 12/4 has 3 hots, and one neutral. The benefit of this cable is that several circuits can be run in one cable, rather than running several different cables.
#3 - FEEDERS
Feeders are one step back from branch-circuits when thinking about a typical electrical system. They are the conductors between the service disconnect and the next panel in the series. This includes anything along that run that is intercepted by equipment such as transformers, disconnects, etc. Feeders go from a breaker to another breaker, including any portion going to anything in-between. Really feeders are everything that is not a branch circuit, or a service-entrance conductor.
#4 - SERVICE-ENTRANCE CONDUCTORS
Service-entrance conductors are those that tie into the utility service-point, in either an overhead or underground service, and run to the main disconnect at the service. These are the first conductors run to a building/structure that we deal with as an electrician. From this main disconnect, any conductors that leave this service panel are either feeders or branch circuit conductors. Many people mistakingly call appliance conductors for furnaces and ac’s feeders, however these are still branch circuits. Feeders begin at a breaker and end at a breaker.
#5 - GROUNDING ELECTRODE
Grounding electrodes are conductive materials installed in the earth, that help to form a bonded connection between earth and the electrical system. They have a conductor (grounding electrode conductor) that bonds the electrode with the equipment grounding conductors and neutrals (grounded conductors) at the service. It’s extremely important that all of these components are bonded together to keep all of them at the same potential. Grounding electrodes can be many different things, including ground-bars, ground-plates, metal water-piping, and rebar in a concrete slab.
CONTINUE READING FULL ARTICLE AT: https://www.electricianu.com/podcast/episode-40-11-more-confusing-code-terms-understanding-the-nec-part-2
#nec #code #electrical
--
Subscribe - https://www.youtube.com/c/electricianu?sub_confirmation=1
IF YOU ENJOY THESE VIDEOS PLEASE SUBSCRIBE AND "LIKE" THEM ABOVE. ALSO CHECK OUT THE ELECTRICIAN U PODCAST ON ITUNES AND SPOTIFY!!
-
0:50
Electrician U
1 year agoWhat Are Lumens?
13.1K4 -
29:07
Tactical Advisor
6 hours agoATF Changes Ruling on SBR & Tacpack unboxing | Vault Room Live Stream 039
56.7K14 -
2:00
From Zero → Viral with AI
11 hours ago $0.73 earnedAre You Being Left Behind? Why AI Marketing is No Longer Optional
26.9K3 -
9:10
BlackDiamondGunsandGear
9 hours agoI Finally Got it! / Now i need to BUILD IT!
19.5K3 -
9:44
Millionaire Mentor
3 days agoCharlie Kirk Brings Woke Student To STUTTERING Over White Privilege Lies
24.1K7 -
24:12
MudandMunitions
10 hours agoOff-Roading with NYPrepper Wild Elk & PA’s Most Remote Backroads
13.9K1 -
LIVE
Bannons War Room
7 months agoWarRoom Live
3,021 watching -
IsaiahLCarter
9 hours ago $0.75 earnedAPOSTATE RADIO 029: Leftist Violence, & NYC's Mayor's Race (Guests: Lattina Brown and David Sivella)
14.4K -
10:03:41
LFA TV
16 hours agoLIVE: CHARLIE KIRK VIGIL SERVICE!
178K65 -
6:59:16
BaldBrad
11 hours agoCharlie Kirk Memorial LIVESTREAM
47.8K7