Premium Only Content

Episode 35 - Why Electricians Need UGLYS - A MINI ELECTRICAL LIBRARY IN YOUR POCKET
Ugly's manuals are time-tested technician approved. Every electrician should have an Ugly's manual with them on every job site they're on, let's talk about some examples as to why.
GET YOUR UGLY's HERE: https://amzn.to/31T0egR
👾🤖PRACTICE EXAMS🤖👾
https://www.electricianu.com/practice-exams
😎👕MERCH👕😎
https://www.electricianu.com/merchandise
📲👥SOCIALS👥📲
Instagram - https://www.instagram.com/electrician_u
Discord - https://discord.gg/7ykYfbh
Facebook Page - https://www.facebook.com/theelectricianu
Facebook Group - https://bit.ly/2tz7eQh
TikTok - https://www.tiktok.com/@electricianu
SPONSOR
ROGERS - https://www.rogersservices.com
Ugly's is an electrical field-reference book that every electrician should have on their jobs. It has so many useful diagrams, schematics, code articles, terms, math and much more. Rather than lugging around a huge 800-page codebook around with you everywhere, you can keep your Ugly's book in your tool pouch or in your pocket when you're on job sites.
Some examples of where you'd use Ugly's are:
SIZING MOTOR CONDUCTORS
You can use the FLC charts in the NEC, or just pull out your Ugly's manual. Ugly's has the FLC charts on single-pages back to back and if you tab the book like I do, they're easily accessible. Say we have a 208v 3-phase 10-horsepower motor on a job, and we need to figure out the current draw so we can decide what conductors to run to it. We'd open up the 3-phase FLC chart, look up 10HP, move over to the 208v column and find that this motor will draw 30.8-amps. Now we have our current and can start to figure out other factors that the motor may have to size the conductors or overcurrent-protection device.
SIZING EQUIPMENT GROUNDING CONDUCTORS
We can use Ugly's to size EGC's as well. We'd simply open the manual to the page labeled "Minimum Size Equipment Grounding Conductors For Grounding Raceway and Equipment." If we have a 100-amp breaker ahead of the piece of equipment, we look at the column to the left and choose 100-amps. Then we move over to the Copper column and see that this piece of equipment should have a #8 grounding conductor run to it.
CONTINUE READING FULL ARTICLE AT: https://www.electricianu.com/podcast/episode-35-why-electricians-need-uglys-a-mini-electrical-library-in-your-pocket
#uglys #electrical #electricianbooks
--
Subscribe - https://www.youtube.com/c/electricianu?sub_confirmation=1
IF YOU ENJOY THESE VIDEOS PLEASE SUBSCRIBE AND "LIKE" THEM ABOVE. ALSO CHECK OUT THE ELECTRICIAN U PODCAST ON ITUNES AND SPOTIFY!!
-
0:58
Electrician U
1 year agoFISH STICKS! Every electrician needs these!
6.3K -
1:54:17
The Charlie Kirk Show
3 hours agoCharlie's Last Trip + What's Next + AMA | Erika Kirk, Mikey McCoy | 9.26.2025
242K213 -
1:02:53
The Quartering
2 hours agoMAGA Kid Kidnapped, Hasan Piker Meltdown, Vivek Fights For Alex Jones & More
111K34 -
32:49
Simply Bitcoin
1 day ago $1.39 earnedBitcoin Crucible w/ Alex Stanczyk | EP 1
24.4K -
1:57:37
Tucker Carlson
2 hours agoCharlie Sheen’s Craziest Hollywood Stories and Why He Refuses to Believe the Official Story of 9/11
46.7K44 -
1:33:12
Sean Unpaved
3 hours agoRyder Cup Tee-Off, CFB's Week 5 Madness, & the NFL's Win-or-Wilt Week 4
26.9K1 -
2:07:01
The Culture War with Tim Pool
4 hours agoWho Really Killed Charlie Kirk? Truth Behind Kirk Assassination | The Culture War with Tim Pool
234K214 -
1:25:28
Lara Logan
14 hours agoTHE REMNANT RISES: Matt Shea & The New Generation of Pastors on Fire for God & Country | Episode 37
39.2K4 -
4:30:51
Nikko Ortiz
6 hours agoADHD, Crashouts, and Karens - Rumble LIVE
85.3K11 -
49:21
Steven Crowder
6 hours agoWhy She's Wrong and other Life Advice from Steven Crowder
226K144