Episode 20 - Fault Detection Devices - GFCI, AFCI, DF, AFGFCI
In this episode I talk about the various fault detecting devices on the market in use in most modern residences. Chiefly Arc Fault and Ground Fault Circuit Interrupters.Â
👾🤖PRACTICE EXAMS🤖👾
https://www.electricianu.com/practice-exams
😎👕MERCH👕😎
https://www.electricianu.com/merchandise
📲👥SOCIALS👥📲
Instagram - https://www.instagram.com/electrician_u
Discord - https://discord.gg/7ykYfbh
Facebook Page - https://www.facebook.com/theelectricianu
Facebook Group - https://bit.ly/2tz7eQh
TikTok - https://www.tiktok.com/@electricianu
GFCI - Ground Fault Circuit Interrupters
GFCI's are devices meant to detect and clear a ground fault. Ground Fault's are exactly as they sound - faults to ground. A fault means a "wrong-doing" or "responsibility for an accident or misfortune" So a ground fault is literally a wrongdoing in an electrical circuit, where an interaction occurs between a hot (un-grounded) conductor, and a ground (grounding conductor). Â
Ground faults can be very dangerous if there is no ground fault protection. If there is too much resistance built up in a circuit current traveling on the ground (grounding conductor) will not trip a breaker and clear the fault. So a person can be introduced into the circuit and get seriously injured. Say a person is in their garage and their washing machine overflows. They open it to take the clothes out and do not realize that a hot (un-grounded conductor) has come loose in the machine and is laying on the casing of the washer. Due to improper equipment grounding and/or bonding methods, the breaker does not trip. There's water all over the floor, the person is barefoot standing in a puddle and goes to open the metal washing machine. That person has just completed the circuit from their hand to their feet, through the water, through the concrete slab and back to the panel. Current just found a far easier (less resistance) path back to the source and this person is now hospitalized for severe electric shock.
This situation could have been avoided had the circuit had GFCI protection on it. When a GFCI device detects a difference in current between the hot and neutral wires inside the device (as little as 5 milli-amperes) it will cause the circuit to disconnect within a tenth of a second. When current finds an alternative path (through the ground or equipment grounding conductor) there is a slight change in the amount of current in the neutral, while the current in the hot wire stays relatively the same. The breaker detects this via a current transformer inside of the device and automatically interrupts the circuit.
For more information on where GFCI protection is needed to safeguard personnel, check out Article 210.8 in the 2017 National Electrical Code.....
To read the rest of this article click here: https://www.electricianu.com/podcast/episode-20-fault-detecting-devices-gfci-afci-afgf-df
--
IF YOU ENJOY THESE VIDEOS PLEASE SUBSCRIBE AND "LIKE" THEM ABOVE. ALSO CHECK OUT THE ELECTRICIAN U PODCAST ON ITUNES!!
#electricianclasses #electricaltraining #electriciantraining #faultdetectiondevices #afci #gfci #afgfci #df
-
0:56
Electrician U
1 year ago90° Drill Attachment!!! - What Hand Tools Are YOU Missing
5.75K1 -
LIVE
The Mel K Show
34 minutes agoMORNINGS WITH MEL K -Armor of God: Humanity Must Choose their Destiny 10-6-25
108 watching -
LIVE
LFA TV
16 hours agoLIVE & BREAKING NEWS! | MONDAY 10/6/25
4,095 watching -
LIVE
Trumpet Daily
26 minutes agoTrumpet Daily LIVE | October 6, 2025
62 watching -
LIVE
Tudor Dixon
1 hour agoRep. Tim Burchett on the Government Shutdown & Leadership Crisis | The Tudor Dixon Podcast
25 watching -
LIVE
Bannons War Room
7 months agoWarRoom Live
10,034 watching -
1:01:24
VINCE
3 hours agoDomestic Terrorism Is Spreading, And Fast | Episode 140 - 10/06/25
132K115 -
40:58
Clownfish TV
5 hours agoHollywood is BROKE and JOBLESS?! Animation Most Affected! | Clownfish TV
8.84K4 -
LIVE
Benny Johnson
2 hours agoTrump Deploys National Guard to Chicago as Democrat Leader Caught CALLING For Murder of Republicans
5,784 watching -
LIVE
Caleb Hammer
12 hours ago$300,000 Of Debt To "Flee Trump’s America" | Financial Audit
140 watching