Premium Only Content

Engineers: 1 of 3 Columns Caused Miami Condo Collapse
Jeff Ostroff analyzes new causes, new visuals, and engineering investigation updates from WJE engineers of the Champlain Towers South Condo collapse in Miami, FL. This engineering update was from a live webinar WJE held in which they revealed the causes of the Champlain Towers South collapse after Condo Association HOA hired them for technical expertise during the class action lawsuit after the collapse of the condo in June 24,2021, killing 98.
📺 Warning Signs: SHOCKING Condo Damage Days Before Miami Collapse
https://youtu.be/cbFPVf1qd10
📺 Champlain Towers South (Surfside, FL) Collapse Investigation from WJE:
https://www.youtube.com/watch?v=2UpjMV9PYgI
📺 NIST Public meeting videos mentioned: https://www.nist.gov/disaster-failure-studies/champlain-towers-south-collapse-ncst-investigation/public-meeting-videos
💻 Miami Herald Article "Surfside tower was flawed from day one. Designs violated the code, likely worsened collapse":
https://www.miamiherald.com/news/local/community/miami-dade/miami-beach/article253200228.html
💻 Surfside condo was ‘screaming’ as an alarming crack formed just weeks before the collapse
https://www.miamiherald.com/news/special-reports/surfside-investigation/article261372582.html#storylink=cpy
💻 An Investigation and Analysis of the 2021 Surfside Condo Collapse Collapse (Ryan L. Blanchard thesis): https://scholarworks.uno.edu/cgi/viewcontent.cgi?article=4245&context=td
00:00 3 Columns on Champlain Towers South Pool Deck
00:38 New Overlay map of Condo collapse pool deck with support columns and beams
03:07 Did the south wall cause Champlain Towers South Condo to collapse?
03:42 Pool deck slab stepdown and Beam "A" removed from 1980 floorplans
05:56 Too Large of Column Spacing? Larger tributary areas
09:06 Finding column K13.1 in condo collapse rubble, column spacing
11:14 WJE structural engineering root cause update
14:10 Miami Herald article shows cracked planters, sagging pool deck
16:17 Excessive concrete cover over rebar rods causes lower shear capacity
17:50 Analysis: Champlain Tower South pool deck was underdesigned for load
20:19 Pool deck column K13.1 had the weakest margin of safety in pool deck
20:41 Morabito Consultants engineers discovered loads on columns Row T exceeded the design
-
UPCOMING
Michael Heaver
3 hours agoItaly Witnesses POWERFUL Election Victory
54 -
UPCOMING
Silver Dragons
15 hours agoIs Silver a Good Buy at an ALL TIME HIGH?
563 -
23:38
Professor Nez
31 minutes agoCandace Owens Just BROKE the Internet with Charlie Kirk BOMBSHELL!
-
LIVE
Side Scrollers Podcast
3 hours agoMASSIVE Netflix Boycott + The TRUTH About Jimmy Kimmel’s Return + BIG Side Scrollers NEWS
360 watching -
LIVE
Sean Unpaved
1 hour agoWild Card Highlights, Eagles' Lucky Streak, Gabriel Takes QB1, & CFB Hot Seat Watch
51 watching -
LIVE
MattMorseTV
2 hours ago $1.63 earned🔴Trump's Press Conference on the SHUTDOWN.🔴
1,001 watching -
LIVE
Viss
3 hours ago🔴LIVE - Position, Strategize, and Outplay The Competition! - PUBG 101
73 watching -
LIVE
Rebel News
1 hour agoOstrich farm update, Imperial Oil layoffs, Smith seeking deals with Ottawa | Buffalo Roundtable
337 watching -
1:28:26
Steven Crowder
4 hours agoThe Left is Violent | Change My Mind
383K850 -
1:35:27
The Mel K Show
1 hour agoMORNINGS WITH MEL K - Bread and Circuses: Do Not Be Distracted 10-1-25
17.6K1