Premium Only Content

Engineers: 1 of 3 Columns Caused Miami Condo Collapse
Jeff Ostroff analyzes new causes, new visuals, and engineering investigation updates from WJE engineers of the Champlain Towers South Condo collapse in Miami, FL. This engineering update was from a live webinar WJE held in which they revealed the causes of the Champlain Towers South collapse after Condo Association HOA hired them for technical expertise during the class action lawsuit after the collapse of the condo in June 24,2021, killing 98.
📺 Warning Signs: SHOCKING Condo Damage Days Before Miami Collapse
https://youtu.be/cbFPVf1qd10
📺 Champlain Towers South (Surfside, FL) Collapse Investigation from WJE:
https://www.youtube.com/watch?v=2UpjMV9PYgI
📺 NIST Public meeting videos mentioned: https://www.nist.gov/disaster-failure-studies/champlain-towers-south-collapse-ncst-investigation/public-meeting-videos
💻 Miami Herald Article "Surfside tower was flawed from day one. Designs violated the code, likely worsened collapse":
https://www.miamiherald.com/news/local/community/miami-dade/miami-beach/article253200228.html
💻 Surfside condo was ‘screaming’ as an alarming crack formed just weeks before the collapse
https://www.miamiherald.com/news/special-reports/surfside-investigation/article261372582.html#storylink=cpy
💻 An Investigation and Analysis of the 2021 Surfside Condo Collapse Collapse (Ryan L. Blanchard thesis): https://scholarworks.uno.edu/cgi/viewcontent.cgi?article=4245&context=td
00:00 3 Columns on Champlain Towers South Pool Deck
00:38 New Overlay map of Condo collapse pool deck with support columns and beams
03:07 Did the south wall cause Champlain Towers South Condo to collapse?
03:42 Pool deck slab stepdown and Beam "A" removed from 1980 floorplans
05:56 Too Large of Column Spacing? Larger tributary areas
09:06 Finding column K13.1 in condo collapse rubble, column spacing
11:14 WJE structural engineering root cause update
14:10 Miami Herald article shows cracked planters, sagging pool deck
16:17 Excessive concrete cover over rebar rods causes lower shear capacity
17:50 Analysis: Champlain Tower South pool deck was underdesigned for load
20:19 Pool deck column K13.1 had the weakest margin of safety in pool deck
20:41 Morabito Consultants engineers discovered loads on columns Row T exceeded the design
-
1:01:38
DeVory Darkins
14 hours ago $48.77 earnedSchumer suffers humiliation as critics applaud Trump's historic peace deal with Tim Pool
110K57 -
56:09
Steven Crowder
19 hours agoBlack Fatigue is Real and I Told Them Why | Black & White on the Gray Issues
518K2.21K -
2:05:36
Inverted World Live
12 hours agoSaint's Tomb Opened for First Time in 800 Years for Ancient Ritual | Ep. 121
102K18 -
2:43:30
TimcastIRL
9 hours agoNY AG Indicted For FRAUD, Faces 30 Years In Prison, $1 MILLION FINE | Timcast IRL
228K110 -
1:09:16
Man in America
19 hours agomRNA 2.0: This Frightening Tech Can Target Your BRAIN Using Biological Post Codes
60.3K23 -
1:28:31
The Charlie Kirk Show
9 hours agoTHOUGHTCRIME Ep. 100 — Turning Point Halftime? Potatoes and Katie Porter? Hasan the Dog Shocker?
119K64 -
6:33:19
SpartakusLIVE
10 hours agoNEW Update, NEW Meta || Zombies Mode is BACK - Smokes NURFED
70.8K5 -
13:10
Robbi On The Record
9 hours ago $9.53 earnedThe War on Christians | China’s Surveillance & Nigeria’s Killing Fields
49.5K36 -
1:24:49
Flyover Conservatives
1 day agoYour Home Just Became a Healing Room — The Truth About Red Light & Med Bed - Jonathan Otto | FOC Show
48.1K9 -
2:11:35
Mally_Mouse
4 days ago🎮 Throwback Thursday! Let's Play: Kingdom Hearts 1 pt. 2
35.5K2