Premium Only Content

Why Your Vista-128BPT is Armed Stay After Choosing Arm Away from TC2
In this video, Joe from Alarm Grid explains why a VISTA-128BPT might Arm Stay when Arming Away when Total Connect 2.0 is used. This is due to an error on Firmware Version 10.0 on a VISTA-128BPT Alarm Panel that makes it impossible to disable the Auto-Stay Arming feature when using Total Connect 2.0.
Auto-Stay Arming tells a system to Arm Stay after Arming Away when no Entry/Exit Zones are faulted during the Exit Delay countdown. Normally, Auto-Stay Arming is ignored when Total Connect 2.0 regardless of programming settings. This is because it is common knowledge that you may use TC2 to Arm Away while you are note around to fault any Entry/Exit Zones.
With that in mind, you would want the system to ignore any Auto-Stay Arming settings when you Arm Away using TC2 and just Arm Away even if you do not fault any Entry/Exit Zones. You only want Auto-Stay Arming as a false alarm preventive measure when you Arm Away from the panel itself. This is because you would likely only be around to fault an Entry/Exit Zone when you Arm on-site from the panel itself.
But if you use Total Connect 2.0 to Arm Away on a VISTA-128BPT running Firmware Version 10.0, then the platform will go based on the zone settings. It will not know to automatically ignore any Auto-Stay Arming settings that are in place. Your only options are to either disable Auto-Stay Arming for each and every zone on the VISTA-128BPT, or upgrade the system to a newer Firmware Version. The issue was fixed in Firmware Version 10.4.
Remember that on a VISTA-128BPT, the Auto-Stay Arming feature is set for individual zones rather than across the entire system or by partitions. If the system is running Firmware Version 10.0, and you have Auto-Stay Arming enabled for a zone, then Auto-Stay Arming will go into effect if you Arm Away from Total Connect 2.0 without faulting an Entry/Exit Zone during the countdown period. The system will then treat that zone as though the system were Armed Stay.
Note: In this video, while in device programming, Joe skips over the AUI? 1=Yes 0=No option. When enabling the keypad that Total Connect 2.0 will emulate, the option of AUI? should be set to 1 for Yes.
https://www.alarmgrid.com/faq/why-is-my-vista-128bpt-armed-stay-after-arming-away-from-tc2
-
3:39
Alarm Grid Home Security DIY Videos
2 years agoQolsys IQ Panel 4: Using Dual Path Monitoring
21 -
LIVE
Wendy Bell Radio
4 hours agoThe Schumer Shutdown
6,121 watching -
LIVE
LFA TV
10 hours agoDEVOTION & BREAKING NEWS! | WEDNESDAY 10/1/25
6,068 watching -
LIVE
Crypto Power Hour
55 minutes agoWTH Is Peer To Peer CryptoCurrency Trading?
196 watching -
1:11:31
JULIE GREEN MINISTRIES
2 hours agoLIVE WITH JULIE
40.5K122 -
35:39
Producer Michael
16 hours agoROLLS-ROYCE SPECTRE TEST DRIVE GOES WRONG!
32.5K4 -
15:42
Nicholas Bowling
15 hours ago $1.79 earnedCharlie’s MURDER Sparks COLLEGE STUDENTS to Boldly Preach the Gospel!
8.88K17 -
40:10
Uncommon Sense In Current Times
18 hours ago $1.52 earnedDeconstruction of Christianity | Tim Barnett on Truth, Faith & the Crisis in Today’s Church
22K2 -
LIVE
Total Horse Channel
12 hours ago2025 Quarter Horse Congress * Celeste Center * Wednesday October 1st
100 watching -
LIVE
The Bubba Army
23 hours agoGOVERNMENT SHUTDOWN! - Bubba the Love Sponge® Show | 10/01/25
1,664 watching